Ultrasonics – Monitoring Ultrasonic Performance

In the blog “Reader Questions – Monitoring Ultrasonic Transducers,” I suggested a couple of ways one might test individual ultrasonic transducers to assure they have not become ineffective due to de-bonding from the cleaning tank.  In an extension of the spirit of that blog, quality control measures for ultrasonic cleaning performance, I decided to check out a paper I …

Reader Questions – Monitoring Ultrasonic Transducers

Today’s blog is responding to two questions asked by readers.   Both concern monitoring of ultrasonic transducer performance. Ralph Clendenin asks – “Is there a measurement of the frequency I need to be aware of during “good” operation I can check monthly that would show reduction in cleaning due to change in frequency?” Stephen Sharkey asks – …

Is It Clean? – Particles – Liquid Particle Counting

In recent blogs we have been talking, for the most part, about particles that are relatively large – ones you can see, touch and feel.  There is a world out there, however, that worries about particles that are very tiny.  I’m talking about particles that are smaller than tens of microns in dimension.  An earlier …

The BIG Four

There are four basic variables that, combined, establish the success or failure of any industrial cleaning process.  The variables are Time, Temperature, Chemistry and Agitation.  Although there may be additional variables – things like fixture design and variations in the process prior to cleaning – which can have major impact and, in fact, make or …